- Home
- Securing Material/ Equipment
- GARO Surge Protection — C Series GPT 350 — 2 + 3-Pole - 230V IT/TT
- Product Information
- Technical Description
- Questions and Answers
- Documentation
- Warranty
Product Information
- Especially adapted for 230V IT/TT networks
- Type 2 surge protection (intermediate protection)
- For systems with or without distributed ground
- No requirement for additional protection (ground fault circuit interrupter/non-flammable enclosure)
Surge protection (SPD) from GARO can be used in all types of power distribution systems. It is designed for mounting on DIN rail and fits under modular cover. Class C / II surge protection specially developed for protection against surges in low voltage installations. Most have replaceable protection modules and housings are halogen-free. Manufactured from flame-resistant PBT or flame-resistant nylon (depending on model). All terminals are made of copper, if aluminum is to be connected, transitions must be used.
For aerial lines, we have a special protection we call GST.
Can be used on systems with and without distributed ground.
From 1.1.2019, surge protection is a mandatory protection in the fuse box when installing a new power circuit for charging electric vehicles. This applies to both a new charging point or charging station.
We are obligated under the regulation on electrical equipment § 21 to inform our customers that all electrical materials intended to be included in a fixed electrical installation can only be installed by an authorized and registered installation company.
Technical Details
Usage | Indoor in fuse box |
---|---|
Grid | IT / TT |
Max continuous operating voltage | 350V (AC) |
Number of poles | 2- and 3-pole |
Type | Varistor class C / II |
Max gG fuse | 250A |
Max impulse current (8/20uS) Imax | 50kA |
Nominal impulse current (8/20us-20ggr) In | 20 kA |
Residual voltage Up | <1,75kV |
Moment | 4,5 Nm |
Operating temperature | - 40ºC - + 80ºC |
Conductor cross-section | Single-core 4-35mm². Stranded/multi-stranded with ferrule 4-25mm² |
Operating temperature | -30°C to +50°C |
Installation | 35mm DIN, according to EN 50022/DIN46277-3 |
Enclosure material | Thermoplastic, UL94 V-0. Self-extinguishing. |
Protection class (IP) | IP20 |
Installation width | 2 modules, DIN 43880 |
Thermal disconnector (internal solder fuse) | Indication flag window: Green = normal. Red = error, replace plug. |
Sales package | 1 pcs |
Volume | 0,194 dm³ (2-pole) 0,292 dm³ (3-pole) |
Package dimensions | 90 x 36 x 60 mm (2-pole) 90 x 54 x 60 mm (3-pole) |
Weight | 100g (2-pole) 130g (3-pole) |
Standards and approval |
IEC61643-11:2011; UL1449 4th |
Warranty | 2 years |
Questions and Answers
Do I need surge protection?
NEK 400:2018, standard 722 power supply for electric vehicles says the following:
It is now a requirement that the connection point must be protected by a surge protector. This can be surge protection that is in front of the entire installation.
The reason is that the number of rechargeable cars that have had their car destroyed as a result of lightning overvoltages or switching overvoltages is sharply increasing. The costs of a repair can amount to several hundred thousand and it is not certain that this is covered by the insurance. It is recommended to disconnect and disconnect the charging equipment during thunderstorms.
Warranty
We are proud of our products and it is important to us that you as a customer are satisfied. That's why we provide a 2-year warranty on most of our products, except consumables. Look for the warranty logo to see what applies to this particular product. Our warranty means that the product should work as expected throughout the warranty period (this in addition to your rights under the Consumer Purchases Act). Read more about the warranty in our terms of purchase.
Related Products
SKU: JFB-B63-4P
AVAILABILITY: In stock
PRODUCT TYPE: Ground fault circuit breaker
VENDOR: CHiNT
Product Information Product Information Fits on DIN-Rails Can be...
2.159 kr eks. mva.
SKU: JFB-B63-2P
AVAILABILITY: Out of Stock
PRODUCT TYPE: Ground fault circuit breaker
VENDOR: CHiNT
Product Information Product Information 2 pole (3 module) which takes up less place in the fuse box Can be used on current courses up to 63A - Trigger current: 30 mA Can only be used on 1-phase courses and works on all...
1.832 kr eks. mva.
SKU: 1631423
AVAILABILITY: In stock
PRODUCT TYPE: Automatic fuse
VENDOR: GARO
Product Information Product Information 2 poles (2 modules) - space-saving in fuse box C-Characteristic - Slow disconnection Can only be used on 1-phase courses and works on all power grids 230V (IT/TT) and 400V (TN) Used in combination with earth...
199 kr eks. mva.
SKU: 1631840
AVAILABILITY: In stock
PRODUCT TYPE: Ground fault circuit breaker
VENDOR: GARO
Product Information Product Information Combined Earth fault circuit breaker 30mA and 2 pole automatic fuse Type A (30mA) - 2 poles (2 modules) - Space saving in the fuse box. C-Characteristic- Slow Disconnection Suitable on all power grids - 230V (IT/TT) and 400V...
559 kr eks. mva.
SKU: 1631450
AVAILABILITY: In stock
PRODUCT TYPE: Ground fault circuit breaker
VENDOR: GARO
Product Information Product Information Earth (ground) Fault Circuit Breaker 1+N - Combined Earth Fault Circuit Breaker 30mA and 1 pole Automatic Fuse Type A (30mA) - (2 modules) - Space Saving in the Fuse Box C-Characteristic- Slow Disconnection Suitable for 400V (TN) Used in combination...
399 kr eks. mva.